A-02YSOF(L)2Y n x 2 Outdoor Telecommunication Cable According To DIN VDE 0816 Part 1


Reference Standard: A-02Y(L)2Y Outdoor Telecommunication Cable according to DIN VDE 0816 Part 1
Application:This cable is used in local telephone networks as subscriber cable
Conductor Material: Solid annealed copper conductor
Insulation Material:Foamed PE (02YS)
Laying-up: Star quads in unit stranding
Wrapping Polyester Tape
Screen Material: Aluminium Foil with copper drain wire
Sheath Material: PE
Sheath Color: Black
Temperature Range: Flexible: -20¡æ to +50¡æ fixed installation: - 40¡ã C to + 70¡ãC
Operating Voltage: 225V

Electrical Performance:

Conductor Diameter (mm)

Insulation Resistance of per km at 20 o C

Min. (GOhms)

Conductor Resistance per km loop

Max. (Ohms)

0.60

5

130

0.80

5

73.2

Size & Dimensions:

A - 02YSOF(L)2Y ... x 2 x 0.8  STIII BD
Part No.
No.of pairs
Outer diameter
£¨mm£©

Cable Weight
£¨kg/km£©

Copper Weight
(kg/km)
CCL-TC-02YSOF6P0.8
6
11.5
150
60
CCL-TC-02YSOF10P08
10
13.0
210
101
CCL-TC-02YSOF20P0.8
20
16.5
360
201
CCL-TC-02YSOF30P0.8
30
19.0
500
302
CCL-TC-02YSOF40P0.8
40
21.0
640
402
CCL-TC-02YSOF50P0.8
50
23.0
775
503
CCL-TC-02YSOF70P0.8
70
27.0
1060
704
CCL-TC-02YSOF100P0.8
100
31.0
1455
1005
CCL-TC-02YSOF150P0.8
150
38.0
2155
1508